Datos del producto:
Contacto
Ahora Charle
|
Modelo no.: | Se aplicará a las empresas de servicios de telecomunicaciones. | Rango de aplicaciones: | Industriales |
---|---|---|---|
Tipo: | Horno de retención eléctrico | Uso: | Secado de cerámica |
El combustible: | Eléctrico | Atmósfera: | El nitrógeno |
Dimensiones efectivas de la cámara: | Se trata de una muestra de las características de los productos. | El termopare: | Tipo K |
Temperatura máxima: | 500ºC | Dimensiones eficaces: | 600*600*600 |
Paquete de transporte: | Envases de madera | Especificación: | 1350*1750*1950mm ((W*H*D) |
Capacidad de producción: | 50 juegos/año | ||
Resaltar: | high temperature box furnace with nitrogen atmosphere,box furnace temperature control stability,Hrf216-05n type box furnace |
1. Applications:
Mainly used for binder burning out(BBO) process of electronic components, ceramic substrates.
2. Mainly Specifics:
Rated Temp. | 350ºC |
Max Temp. | 500ºC |
Effective Dimensions | 600 × 600 × 600mm(W×H×D) |
Heating Method | Stainless Steel Heater |
Process Atmosphere | Nitrogen |
Temperature Control Stability | ±1ºC, with PID parameter self-tuning function |
Temperature Uniformity | better than ±5ºC (insulation 1 hour at 400ºC test) |
Thermocouple | Type K |
Temperature measurement points |
1 point |
Process Steps | 4 × 10 steps |
Exhaust | One exhaust port on top |
Max Heating Power | 18kW |
Insulation Power | ≤ 12kW |
Surface Temperature Rise | ≤ 35ºC |
3. Delivery List | |||
Item | Note | QTY | |
Basic Compositions | Dryer | 1 PC | |
Certificates of Inspection | Dryer and major purchased components | 1 Set | |
Technical Documents | Manual instructions, technical documents of major purchased components, etc | 1 Set | |
Key Parts | Heating Elements | Stainless Steel Heater | 1 Set |
Thermocouple | WATLOW/THERMOWAY, Type K | 1 PC | |
Temperature Controller | 1 Set | ||
Monitor | Touch screen | 1 Set | |
Spares | SSR | 1 PC |
4. Facility Requirements
4.1 Environmental conditions: Temperature 0 - 40ºC, humidity ≤ 80% RH, no corrosive gas, no strong
airflow disturbance.
4.2 Process air conditions: 99.999% purity nitrogen, pressure 0.2 - 0.4Mpa, gas consumption 10m3 /h.
4.3 Ventilation system: non-contact access to the user pumping system, pumping capacity is greater
than 15m3 /h;
4.4 Ground requirements: level, no obvious vibration, bearing capacity >300Kg/m2 .
4.5 Power conditions: capacity greater than 24kVA, 3 phases 5 lines, voltage 220/380V, frequency
50Hz(according to local situation). Live wire: yellow, green, red, neutral wire: blue, ground wire: yellow-green;
4.6 Installation site: 2000mm×3000mm×3000mm (W×H×D), installation area greater than 6m2.
Persona de Contacto: zang
Teléfono: 18010872860
Fax: 86-0551-62576378