Casa Prodottiforno a muffa a vuoto

Hwf80-04n Ultra-Low Oxygen Content (Less than 50 ppm) Programmable Hydrogen Removal Furnace Muffle Furnace

Rassegne del cliente
Caro partner, Grazie per il vostro sostegno e la vostra fiducia nel corso dell'ultimo anno.Non vediamo l'ora di proseguire la nostra stretta collaborazione e di creare insieme un valore ancora maggiore.. Con i migliori saluti, [Accademia Cinese delle Scienze]

—— Accademia cinese delle scienze

Sono ora online in chat

Hwf80-04n Ultra-Low Oxygen Content (Less than 50 ppm) Programmable Hydrogen Removal Furnace Muffle Furnace

Hwf80-04n Ultra-Low Oxygen Content (Less than 50 ppm) Programmable Hydrogen Removal Furnace Muffle Furnace
Hwf80-04n Ultra-Low Oxygen Content (Less than 50 ppm) Programmable Hydrogen Removal Furnace Muffle Furnace Hwf80-04n Ultra-Low Oxygen Content (Less than 50 ppm) Programmable Hydrogen Removal Furnace Muffle Furnace Hwf80-04n Ultra-Low Oxygen Content (Less than 50 ppm) Programmable Hydrogen Removal Furnace Muffle Furnace Hwf80-04n Ultra-Low Oxygen Content (Less than 50 ppm) Programmable Hydrogen Removal Furnace Muffle Furnace Hwf80-04n Ultra-Low Oxygen Content (Less than 50 ppm) Programmable Hydrogen Removal Furnace Muffle Furnace Hwf80-04n Ultra-Low Oxygen Content (Less than 50 ppm) Programmable Hydrogen Removal Furnace Muffle Furnace Hwf80-04n Ultra-Low Oxygen Content (Less than 50 ppm) Programmable Hydrogen Removal Furnace Muffle Furnace Hwf80-04n Ultra-Low Oxygen Content (Less than 50 ppm) Programmable Hydrogen Removal Furnace Muffle Furnace Hwf80-04n Ultra-Low Oxygen Content (Less than 50 ppm) Programmable Hydrogen Removal Furnace Muffle Furnace Hwf80-04n Ultra-Low Oxygen Content (Less than 50 ppm) Programmable Hydrogen Removal Furnace Muffle Furnace Hwf80-04n Ultra-Low Oxygen Content (Less than 50 ppm) Programmable Hydrogen Removal Furnace Muffle Furnace Hwf80-04n Ultra-Low Oxygen Content (Less than 50 ppm) Programmable Hydrogen Removal Furnace Muffle Furnace

Grande immagine :  Hwf80-04n Ultra-Low Oxygen Content (Less than 50 ppm) Programmable Hydrogen Removal Furnace Muffle Furnace

Dettagli:
Luogo di origine: Cina
Marca: Chitherm
Numero di modello: HWF80-04N
Termini di pagamento e spedizione:
Quantità di ordine minimo: 1
Prezzo: negotiable
Imballaggi particolari: Imballaggio in legno
Tempi di consegna: 90 giorni di lavoro
Termini di pagamento: T/T, L/C
Capacità di alimentazione: 50 set/anno
Contatto Ora chiacchieri

Hwf80-04n Ultra-Low Oxygen Content (Less than 50 ppm) Programmable Hydrogen Removal Furnace Muffle Furnace

descrizione
Modello n.: HWF80-04N Tipo: Fornace di tenuta elettrica
Utilizzo: Sintering ceramico Carburante: Elettrico
Atmosfera: Vaso/azoto Dimensioni della camera efficaci: 400*400*500mm (W*H*D)
temperatura massima: 400 ° C. Potenza di riscaldamento massima: 15KW
Potenza isolamento forno a riposo: ≤7.5kw Precisione del controllo della temperatura: ± 1 ° C.
Tipo di termocoppia: Tipo K Pacchetto di trasporto: Imballaggio in legno
Specifica: 1500*1950*1750mm ((W*H*D) Marchio: CHITHERM
Origine: Cina Codice Hs: 8514101000
Capacità di alimentazione: 50 set/anno Dimensioni del pacchetto: 1550.00cm * 1960.00cm * 1760.00cm
PACCHETTO Peso lordo: 1000.000 kg Personalizzazione: Disponibile
Place Style: Verticale Gamma di applicazioni: Industriale
Costo di spedizione: Contattare il fornitore per trasporto e tempi di consegna stimati.  : Supportare i pagamenti in USD
Pagamenti sicuri: Ogni pagamento effettuato su Made in-China.com è protetto dalla piattaforma. Politica di rimborso: Richiedi un rimborso se il tuo ordine non spedisce, manca o arriva con problemi di prodotto.

Hwf80-04n Ultra-Low Oxygen Content (Less than 50 ppm) Programmable Hydrogen Removal Furnace Muffle Furnace 0I. Basic Equipment Information
Equipment Name: Hydrogen Removal Furnace
Equipment Model: HWF80-04N
Application Fields: Heat treatment processes including decarburization, hydrogen removal, annealing, tempering, and binder removal
Equipment Weight: Approximately 1000kg
Equipment Color: Light gray
Reference Overall Dimensions: 1500×1950×1750mm (W×H×D); actual dimensions subject to the final product
II. Core Technical Indicators
Rated Temperature: 350℃ (unlimited holding time at platform temperature)
Maximum Temperature: 400℃
Tank Material: SUS316L
Effective Dimensions: 400×400×500mm (W×H×D)
Loading Method: Manual loading; horizontal guide rails and material racks are installed inside the tank
Heating Element: Internal heating with stainless steel heating tubes
Heating Method: Hot air circulation heating
Maximum Heating Power: 15kW
No-Load Heat Preservation Power: ≤7.5kW
Heating Rate: ≤5℃/min
Temperature Control Precision: ±1℃, with PID parameter self-tuning function
Temperature Uniformity: ±5℃ (tested under no-load condition at 350℃ for 1 hour)
Thermocouple Type: K-type
Temperature Control Points: 1 point
Temperature Measurement Method: Reserved detection port for installing an armored flexible thermocouple for real-time monitoring
Program Steps: 20 steps
Sintering Atmosphere: Vacuum/Nitrogen
Oxygen Detection Configuration: Equipped with one micro-oxygen analyzer for detecting the oxygen content inside the tank (under positive pressure inert atmosphere inside the tank)
Oxygen Content: ≤50ppm
Ultimate Vacuum Degree: 10⁻²Pa (under no-load, clean, room temperature, and fully degassed conditions)
Vacuum Pumping Time: ≤60 minutes to reach 10⁻²Pa from atmospheric pressure
Cooling Method: Furnace cooling; time from 350℃ to room temperature <12 hours
Number of Exhaust Ports: 1
Surface Temperature Rise: <35℃
Alarm Protection Function: Audio-visual alarm protection for over-temperature, thermocouple breakage, low air pressure, low water pressure, motor phase loss, etc.; equipped with over-temperature alarm and heating cut-off protection function
III. Installation and Operating Conditions
Environmental Conditions: Temperature 0~40℃, humidity ≤80%RH, no corrosive gases, no strong air disturbance
Nitrogen Conditions: Gas source pressure 0.2~0.4Mpa, purity 99.999%, gas consumption 2~6m³/h
Ventilation Gas Source Conditions: Clean, dry, oil-free compressed air with pressure 0.4~0.8Mpa
Water Inlet Conditions: Pressure 0.1~0.3Mpa, clean, non-corrosive, supply flow 1~3L/min
Ventilation System: Non-contact connection to the user's air extraction system with an extraction capacity >10m³/h
Floor Requirements: Level, no obvious vibration, load-bearing capacity >500kg/m²
Power Supply Conditions: Capacity >22kVA, 3-phase 5-wire system, voltage 220/380V, frequency 50Hz; Live wires: yellow, green, red; Neutral wire: blue; Ground wire: yellow-green
Installation Site: Dimensions 3000mm×2500mm×3000mm (D×W×H), installation area >8m²Hwf80-04n Ultra-Low Oxygen Content (Less than 50 ppm) Programmable Hydrogen Removal Furnace Muffle Furnace 1 
 