Dom Produktypieca podciśnieniowa

Hwf80-04n Ultra-Low Oxygen Content (Less than 50 ppm) Programmable Hydrogen Removal Furnace Muffle Furnace

Opinie klientów
Drogi partnerze, Dziękujemy za wsparcie i zaufanie w ciągu ostatniego roku.Z niecierpliwością czekamy na dalszą bliską współpracę i stworzenie jeszcze większej wartości. Z największymi pozdrowieniami, [Chińska Akademia Nauk]

—— Chińska Akademia Nauk

Im Online Czat teraz

Hwf80-04n Ultra-Low Oxygen Content (Less than 50 ppm) Programmable Hydrogen Removal Furnace Muffle Furnace

Hwf80-04n Ultra-Low Oxygen Content (Less than 50 ppm) Programmable Hydrogen Removal Furnace Muffle Furnace
Hwf80-04n Ultra-Low Oxygen Content (Less than 50 ppm) Programmable Hydrogen Removal Furnace Muffle Furnace Hwf80-04n Ultra-Low Oxygen Content (Less than 50 ppm) Programmable Hydrogen Removal Furnace Muffle Furnace Hwf80-04n Ultra-Low Oxygen Content (Less than 50 ppm) Programmable Hydrogen Removal Furnace Muffle Furnace Hwf80-04n Ultra-Low Oxygen Content (Less than 50 ppm) Programmable Hydrogen Removal Furnace Muffle Furnace Hwf80-04n Ultra-Low Oxygen Content (Less than 50 ppm) Programmable Hydrogen Removal Furnace Muffle Furnace Hwf80-04n Ultra-Low Oxygen Content (Less than 50 ppm) Programmable Hydrogen Removal Furnace Muffle Furnace Hwf80-04n Ultra-Low Oxygen Content (Less than 50 ppm) Programmable Hydrogen Removal Furnace Muffle Furnace Hwf80-04n Ultra-Low Oxygen Content (Less than 50 ppm) Programmable Hydrogen Removal Furnace Muffle Furnace Hwf80-04n Ultra-Low Oxygen Content (Less than 50 ppm) Programmable Hydrogen Removal Furnace Muffle Furnace Hwf80-04n Ultra-Low Oxygen Content (Less than 50 ppm) Programmable Hydrogen Removal Furnace Muffle Furnace Hwf80-04n Ultra-Low Oxygen Content (Less than 50 ppm) Programmable Hydrogen Removal Furnace Muffle Furnace Hwf80-04n Ultra-Low Oxygen Content (Less than 50 ppm) Programmable Hydrogen Removal Furnace Muffle Furnace

Duży Obraz :  Hwf80-04n Ultra-Low Oxygen Content (Less than 50 ppm) Programmable Hydrogen Removal Furnace Muffle Furnace

Szczegóły Produktu:
Miejsce pochodzenia: Chiny
Nazwa handlowa: Chitherm
Numer modelu: HWF80-04N
Zapłata:
Minimalne zamówienie: 1
Cena: negotiable
Szczegóły pakowania: Opakowanie drewniane
Czas dostawy: 90 dni roboczych
Zasady płatności: T/T, akredytywa
Możliwość Supply: 50 zestawów/rok
Kontakt Rozmawiaj teraz.

Hwf80-04n Ultra-Low Oxygen Content (Less than 50 ppm) Programmable Hydrogen Removal Furnace Muffle Furnace

Opis
Nr modelu: HWF80-04N Typ: Elektryczny piec trzymający
Stosowanie: Spiekanie ceramiczne Paliwo: Elektryczny
Atmosfera: Próżnia/azot Skuteczne wymiary komory: 400*400*500 mm (w*h*d)
maksymalna temperatura: 400 ° C. Maksymalna moc ogrzewania: 15 kW
Moc izolacyjna pieca bezczynna: ≤7,5 kW Dokładność kontroli temperatury: ± 1 ° C.
Typ termopary: Typ K Pakiet Transportowy: Opakowanie drewniane
Specyfikacja: 1500*1950*1750 mm (w*h*d) Znak firmowy: Chitherm
Pochodzenie: Chiny Kod Hs: 8514101000
Możliwość Supply: 50 zestawów/rok Rozmiar pakietu: 1550,00 cm * 1960,00 cm * 1760,00 cm
Waga brutto pakietu: 1000 000 kg Personalizacja: Dostępny
Styl miejsca: Pionowy Zakres aplikacji: Przemysłowy
Koszt wysyłki: Skontaktuj się z dostawcą w sprawie frachtu i szacowanego czasu dostawy.  : Płatności wsparcia w USD
Bezpieczne płatności: Każda płatność, którą dokonujesz na Made-Inchina.com, jest chroniona przez platformę. Zwróć politykę: Uważaj na zwrot pieniędzy, jeśli zamówienie nie wysyła, brakuje lub przybywa z problemami z produkte

Hwf80-04n Ultra-Low Oxygen Content (Less than 50 ppm) Programmable Hydrogen Removal Furnace Muffle Furnace 0I. Basic Equipment Information
Equipment Name: Hydrogen Removal Furnace
Equipment Model: HWF80-04N
Application Fields: Heat treatment processes including decarburization, hydrogen removal, annealing, tempering, and binder removal
Equipment Weight: Approximately 1000kg
Equipment Color: Light gray
Reference Overall Dimensions: 1500×1950×1750mm (W×H×D); actual dimensions subject to the final product
II. Core Technical Indicators
Rated Temperature: 350℃ (unlimited holding time at platform temperature)
Maximum Temperature: 400℃
Tank Material: SUS316L
Effective Dimensions: 400×400×500mm (W×H×D)
Loading Method: Manual loading; horizontal guide rails and material racks are installed inside the tank
Heating Element: Internal heating with stainless steel heating tubes
Heating Method: Hot air circulation heating
Maximum Heating Power: 15kW
No-Load Heat Preservation Power: ≤7.5kW
Heating Rate: ≤5℃/min
Temperature Control Precision: ±1℃, with PID parameter self-tuning function
Temperature Uniformity: ±5℃ (tested under no-load condition at 350℃ for 1 hour)
Thermocouple Type: K-type
Temperature Control Points: 1 point
Temperature Measurement Method: Reserved detection port for installing an armored flexible thermocouple for real-time monitoring
Program Steps: 20 steps
Sintering Atmosphere: Vacuum/Nitrogen
Oxygen Detection Configuration: Equipped with one micro-oxygen analyzer for detecting the oxygen content inside the tank (under positive pressure inert atmosphere inside the tank)
Oxygen Content: ≤50ppm
Ultimate Vacuum Degree: 10⁻²Pa (under no-load, clean, room temperature, and fully degassed conditions)
Vacuum Pumping Time: ≤60 minutes to reach 10⁻²Pa from atmospheric pressure
Cooling Method: Furnace cooling; time from 350℃ to room temperature <12 hours
Number of Exhaust Ports: 1
Surface Temperature Rise: <35℃
Alarm Protection Function: Audio-visual alarm protection for over-temperature, thermocouple breakage, low air pressure, low water pressure, motor phase loss, etc.; equipped with over-temperature alarm and heating cut-off protection function
III. Installation and Operating Conditions
Environmental Conditions: Temperature 0~40℃, humidity ≤80%RH, no corrosive gases, no strong air disturbance
Nitrogen Conditions: Gas source pressure 0.2~0.4Mpa, purity 99.999%, gas consumption 2~6m³/h
Ventilation Gas Source Conditions: Clean, dry, oil-free compressed air with pressure 0.4~0.8Mpa
Water Inlet Conditions: Pressure 0.1~0.3Mpa, clean, non-corrosive, supply flow 1~3L/min
Ventilation System: Non-contact connection to the user's air extraction system with an extraction capacity >10m³/h
Floor Requirements: Level, no obvious vibration, load-bearing capacity >500kg/m²
Power Supply Conditions: Capacity >22kVA, 3-phase 5-wire system, voltage 220/380V, frequency 50Hz; Live wires: yellow, green, red; Neutral wire: blue; Ground wire: yellow-green
Installation Site: Dimensions 3000mm×2500mm×3000mm (D×W×H), installation area >8m²Hwf80-04n Ultra-Low Oxygen Content (Less than 50 ppm) Programmable Hydrogen Removal Furnace Muffle Furnace 1 
 