Casa ProdutosForno de muffle a vácuo

Hwf80-04n Ultra-Low Oxygen Content (Less than 50 ppm) Programmable Hydrogen Removal Furnace Muffle Furnace

Revisões do cliente
Caro Valorizado Parceiro, Agradecemos o vosso apoio e confiança no ano passado, é graças à vossa cooperação que conseguimos alcançar com êxito os nossos objectivos.Esperamos continuar a nossa estreita colaboração e criar ainda mais valor juntos. Com os melhores cumprimentos,

—— Academia Chinesa de Ciências

Estou Chat Online Agora

Hwf80-04n Ultra-Low Oxygen Content (Less than 50 ppm) Programmable Hydrogen Removal Furnace Muffle Furnace

Hwf80-04n Ultra-Low Oxygen Content (Less than 50 ppm) Programmable Hydrogen Removal Furnace Muffle Furnace
Hwf80-04n Ultra-Low Oxygen Content (Less than 50 ppm) Programmable Hydrogen Removal Furnace Muffle Furnace Hwf80-04n Ultra-Low Oxygen Content (Less than 50 ppm) Programmable Hydrogen Removal Furnace Muffle Furnace Hwf80-04n Ultra-Low Oxygen Content (Less than 50 ppm) Programmable Hydrogen Removal Furnace Muffle Furnace Hwf80-04n Ultra-Low Oxygen Content (Less than 50 ppm) Programmable Hydrogen Removal Furnace Muffle Furnace Hwf80-04n Ultra-Low Oxygen Content (Less than 50 ppm) Programmable Hydrogen Removal Furnace Muffle Furnace Hwf80-04n Ultra-Low Oxygen Content (Less than 50 ppm) Programmable Hydrogen Removal Furnace Muffle Furnace Hwf80-04n Ultra-Low Oxygen Content (Less than 50 ppm) Programmable Hydrogen Removal Furnace Muffle Furnace Hwf80-04n Ultra-Low Oxygen Content (Less than 50 ppm) Programmable Hydrogen Removal Furnace Muffle Furnace Hwf80-04n Ultra-Low Oxygen Content (Less than 50 ppm) Programmable Hydrogen Removal Furnace Muffle Furnace Hwf80-04n Ultra-Low Oxygen Content (Less than 50 ppm) Programmable Hydrogen Removal Furnace Muffle Furnace Hwf80-04n Ultra-Low Oxygen Content (Less than 50 ppm) Programmable Hydrogen Removal Furnace Muffle Furnace Hwf80-04n Ultra-Low Oxygen Content (Less than 50 ppm) Programmable Hydrogen Removal Furnace Muffle Furnace

Imagem Grande :  Hwf80-04n Ultra-Low Oxygen Content (Less than 50 ppm) Programmable Hydrogen Removal Furnace Muffle Furnace

Detalhes do produto:
Lugar de origem: China
Marca: Chitherm
Número do modelo: HWF80-04N
Condições de Pagamento e Envio:
Quantidade de ordem mínima: 1
Preço: negotiable
Detalhes da embalagem: Embalagem de madeira
Tempo de entrega: 90 dias de trabalho
Termos de pagamento: T/T,L/C
Habilidade da fonte: 50 conjuntos/ano
Contato Converse agora

Hwf80-04n Ultra-Low Oxygen Content (Less than 50 ppm) Programmable Hydrogen Removal Furnace Muffle Furnace

descrição
Modelo não.: HWF80-04N Tipo: Furno de retenção elétrica
Uso: Sinterização de cerâmica Combustível: Elétrico
Atmosfera: Vazio/nitrogénio Dimensões eficazes da câmara: 400*400*500mm (W*H*D)
temperatura máxima: 400 ° C. Poder de aquecimento máximo: 15kw
Potência de isolamento do forno a inatividade: ≤ 7,5 kW Precisão do controle de temperatura: ± 1 ° C.
Tipo de termocouple: Tipo K Pacote de Transporte: Embalagem de madeira
Especificação: 1500*1950*1750mm (L*A*P) Marca registrada: Chitherm
Origem: China Código Hs: 8514101000
Habilidade da fonte: 50 conjuntos/ano Tamanho do pacote: 1550.00cm * 1960.00cm * 1760.00cm
Pacote de peso bruto: 1000.000 kg Personalização: Disponível
Estilo de lugar: Vertical Gama de aplicações: Industrial
Custo de envio: Entre em contato com o fornecedor sobre o frete e o tempo estimado de entrega.  : Apoiar pagamentos em USD
Pagamentos seguros: Todo pagamento que você faz no Made in china.com é protegido pela plataforma. Política de reembolso: Reivindicar um reembolso se o seu pedido não for enviar, está ausente ou chegar com problemas de pro

Hwf80-04n Ultra-Low Oxygen Content (Less than 50 ppm) Programmable Hydrogen Removal Furnace Muffle Furnace 0I. Basic Equipment Information
Equipment Name: Hydrogen Removal Furnace
Equipment Model: HWF80-04N
Application Fields: Heat treatment processes including decarburization, hydrogen removal, annealing, tempering, and binder removal
Equipment Weight: Approximately 1000kg
Equipment Color: Light gray
Reference Overall Dimensions: 1500×1950×1750mm (W×H×D); actual dimensions subject to the final product
II. Core Technical Indicators
Rated Temperature: 350℃ (unlimited holding time at platform temperature)
Maximum Temperature: 400℃
Tank Material: SUS316L
Effective Dimensions: 400×400×500mm (W×H×D)
Loading Method: Manual loading; horizontal guide rails and material racks are installed inside the tank
Heating Element: Internal heating with stainless steel heating tubes
Heating Method: Hot air circulation heating
Maximum Heating Power: 15kW
No-Load Heat Preservation Power: ≤7.5kW
Heating Rate: ≤5℃/min
Temperature Control Precision: ±1℃, with PID parameter self-tuning function
Temperature Uniformity: ±5℃ (tested under no-load condition at 350℃ for 1 hour)
Thermocouple Type: K-type
Temperature Control Points: 1 point
Temperature Measurement Method: Reserved detection port for installing an armored flexible thermocouple for real-time monitoring
Program Steps: 20 steps
Sintering Atmosphere: Vacuum/Nitrogen
Oxygen Detection Configuration: Equipped with one micro-oxygen analyzer for detecting the oxygen content inside the tank (under positive pressure inert atmosphere inside the tank)
Oxygen Content: ≤50ppm
Ultimate Vacuum Degree: 10⁻²Pa (under no-load, clean, room temperature, and fully degassed conditions)
Vacuum Pumping Time: ≤60 minutes to reach 10⁻²Pa from atmospheric pressure
Cooling Method: Furnace cooling; time from 350℃ to room temperature <12 hours
Number of Exhaust Ports: 1
Surface Temperature Rise: <35℃
Alarm Protection Function: Audio-visual alarm protection for over-temperature, thermocouple breakage, low air pressure, low water pressure, motor phase loss, etc.; equipped with over-temperature alarm and heating cut-off protection function
III. Installation and Operating Conditions
Environmental Conditions: Temperature 0~40℃, humidity ≤80%RH, no corrosive gases, no strong air disturbance
Nitrogen Conditions: Gas source pressure 0.2~0.4Mpa, purity 99.999%, gas consumption 2~6m³/h
Ventilation Gas Source Conditions: Clean, dry, oil-free compressed air with pressure 0.4~0.8Mpa
Water Inlet Conditions: Pressure 0.1~0.3Mpa, clean, non-corrosive, supply flow 1~3L/min
Ventilation System: Non-contact connection to the user's air extraction system with an extraction capacity >10m³/h
Floor Requirements: Level, no obvious vibration, load-bearing capacity >500kg/m²
Power Supply Conditions: Capacity >22kVA, 3-phase 5-wire system, voltage 220/380V, frequency 50Hz; Live wires: yellow, green, red; Neutral wire: blue; Ground wire: yellow-green
Installation Site: Dimensions 3000mm×2500mm×3000mm (D×W×H), installation area >8m²Hwf80-04n Ultra-Low Oxygen Content (Less than 50 ppm) Programmable Hydrogen Removal Furnace Muffle Furnace 1 
 