Rumah ProdukOven Muffle vakum

HWF80-04N Series Precision Atmosphere-Controlled Vacuum Muffle Furnace with 400°C Max Temperature 15kW Heating Power and ±1°C Accuracy

Ulasan pelanggan
Rekan yang terhormat, Terima kasih atas dukungan dan kepercayaan Anda selama setahun terakhir. Karena kerja sama Anda, kami berhasil mencapai tujuan kami.kami berharap untuk melanjutkan kerjasama dekat kami dan menciptakan nilai yang lebih besar bersama-sama. Dengan salam hangat, [Academy of Sciences China]

—— Akademi Ilmu Pengetahuan Cina

I 'm Online Chat Now

HWF80-04N Series Precision Atmosphere-Controlled Vacuum Muffle Furnace with 400°C Max Temperature 15kW Heating Power and ±1°C Accuracy

HWF80-04N Series Precision Atmosphere-Controlled Vacuum Muffle Furnace with 400°C Max Temperature 15kW Heating Power and ±1°C Accuracy
HWF80-04N Series Precision Atmosphere-Controlled Vacuum Muffle Furnace with 400°C Max Temperature 15kW Heating Power and ±1°C Accuracy HWF80-04N Series Precision Atmosphere-Controlled Vacuum Muffle Furnace with 400°C Max Temperature 15kW Heating Power and ±1°C Accuracy HWF80-04N Series Precision Atmosphere-Controlled Vacuum Muffle Furnace with 400°C Max Temperature 15kW Heating Power and ±1°C Accuracy HWF80-04N Series Precision Atmosphere-Controlled Vacuum Muffle Furnace with 400°C Max Temperature 15kW Heating Power and ±1°C Accuracy HWF80-04N Series Precision Atmosphere-Controlled Vacuum Muffle Furnace with 400°C Max Temperature 15kW Heating Power and ±1°C Accuracy HWF80-04N Series Precision Atmosphere-Controlled Vacuum Muffle Furnace with 400°C Max Temperature 15kW Heating Power and ±1°C Accuracy HWF80-04N Series Precision Atmosphere-Controlled Vacuum Muffle Furnace with 400°C Max Temperature 15kW Heating Power and ±1°C Accuracy HWF80-04N Series Precision Atmosphere-Controlled Vacuum Muffle Furnace with 400°C Max Temperature 15kW Heating Power and ±1°C Accuracy HWF80-04N Series Precision Atmosphere-Controlled Vacuum Muffle Furnace with 400°C Max Temperature 15kW Heating Power and ±1°C Accuracy HWF80-04N Series Precision Atmosphere-Controlled Vacuum Muffle Furnace with 400°C Max Temperature 15kW Heating Power and ±1°C Accuracy

Gambar besar :  HWF80-04N Series Precision Atmosphere-Controlled Vacuum Muffle Furnace with 400°C Max Temperature 15kW Heating Power and ±1°C Accuracy

Detail produk:
Tempat asal: Tiongkok
Nama merek: Chitherm
Nomor model: HWF80-04N
Syarat-syarat pembayaran & pengiriman:
Kuantitas min Order: 1
Harga: negotiable
Kemasan rincian: Kemasan kayu
Waktu pengiriman: 90 hari kerja
Syarat-syarat pembayaran: T/T,L/C
Menyediakan kemampuan: 50 set/tahun
Kontak bicara sekarang

HWF80-04N Series Precision Atmosphere-Controlled Vacuum Muffle Furnace with 400°C Max Temperature 15kW Heating Power and ±1°C Accuracy

Deskripsi
Nomor Model.: HWF80-04N Jenis: Tungku penahan listrik
Penggunaan: Sintering keramik Bahan bakar: Listrik
Suasana: Vakum/nitrogen Dimensi ruang yang efektif: 400*400*500mm (w*h*d)
suhu maksimum: 400°C Daya pemanas maksimum: 15kw
Daya isolasi tungku idle: ≤7.5kw Akurasi kontrol suhu: ± 1 ° C.
Tipe Termokopel: Tipe K Paket Transportasi: Kemasan kayu
Spesifikasi: 1500*1950*1750mm (w*h*d) Merek dagang: Chitherh
Asal: Tiongkok Kode Hs: 8514101000
Menyediakan kemampuan: 50 set/tahun Ukuran paket: 1550.00cm * 1960.00cm * 1760.00cm
Paket berat kotor: 1000.000kg Kustomisasi: Tersedia
Gaya tempat: Vertikal Rentang aplikasi: Industri
Biaya pengiriman: Hubungi pemasok tentang pengiriman dan perkiraan waktu pengiriman.  : Mendukung pembayaran di USD
Pembayaran aman: Setiap pembayaran yang Anda lakukan di dibuat-in-china.com dilindungi oleh platform. Kebijakan Pengembalian dana: Klaim pengembalian uang jika pesanan Anda tidak dikirim, hilang, atau tiba dengan masalah produk.
Menyoroti:

400°C Maximum Temperature Vacuum Muffle Furnace

,

15kW Maximum Heating Power Precision Atmosphere-Controlled Furnace

,

±1°C Temperature Control Accuracy Electric Holding Furnace

HWF80-04N Series Precision Atmosphere-Controlled Vacuum Furnace Muffle Furnace
HWF80-04N Series Precision Atmosphere-Controlled Vacuum Muffle Furnace with 400°C Max Temperature 15kW Heating Power and ±1°C Accuracy 0
Basic Equipment Information
Item Details
Equipment Model HWF80-04N Type Hydrogen Removal Furnace
Application Field Heat treatment processes such as decarburization, hydrogen removal, annealing, tempering, and binder removal
Equipment Weight Approximately 1000kg
Equipment Color Light gray
Reference Overall Dimensions 1500×1950×1750mm (W×H×D), subject to the actual product
Installation Site Dimensions 3000mm×2500mm×3000mm (D×W×H), installation area ≥8m²
Core Technical Indicators
Temperature-related
  • Rated Temperature: 350ºC (unlimited holding time); Maximum Temperature: 400ºC
  • Heating Rate: ≤5ºC/min; Temperature Control Accuracy: ±1ºC (with PID parameter self-tuning function)
  • Temperature Uniformity: ±5ºC (tested in empty furnace at 350ºC for 1h under constant temperature)
  • Cooling Method: Furnace cooling (time from 350ºC to room temperature <12h)
  • Heating Method: Hot air circulation heating
  • Heating Element: Internal heating with stainless steel heating tubes
  • Maximum Heating Power: 15kW; Empty Furnace Holding Power: ≤7.5kW
  • Thermocouple Type: K grade
  • Temperature Control Points: 1 point (reserved detection port for installing armored flexible thermocouple for real-time monitoring)
Atmosphere and Vacuum-related
  • Sintering Atmosphere: Vacuum/Nitrogen
  • Ultimate Vacuum Degree: 10-²Pa (empty furnace, clean, room temperature, fully degassed)
  • Vacuum Pumping Time: ≤60min (from atmospheric pressure to 10-²Pa)
  • Oxygen Content: Better than 50ppm (under positive pressure inert atmosphere)
  • Equipped with a micro-oxygen analyzer to detect oxygen content inside the tank
  • Number of Exhaust Ports: 1
Structure and Safety
  • Tank Material: SUS316L
  • Effective Dimensions: 400×400×500mm (W×H×D)
  • Loading Method: Manual loading, with horizontal guide rails and racks inside the tank
  • Surface Temperature Rise: <35ºC
  • Alarm Protection: Acoustic and optical alarm protection for over-temperature, thermocouple breakage, low air pressure, low water pressure, motor under/over phase, etc., and over-temperature alarm to cut off heating protection function
Installation and Operation Conditions
  • Environmental Conditions: Temperature 0~40ºC, Humidity ≤80%RH, no corrosive gas, no strong air disturbance
  • Nitrogen: Pressure 0.2~0.4Mpa, Purity 99.999%, Gas Consumption 2~6m³/h
  • Compressed Air: Clean, dry, oil-free, Pressure 0.4~0.8Mpa
  • Water Inlet Conditions: Pressure 0.1~0.3Mpa, clean, non-corrosive, supply flow rate 1~3L/min
  • Ventilation System: Non-contact connection to the user's air extraction system, extraction capacity >10m³/h
  • Ground Requirements: Level, no obvious vibration, load-bearing capacity >500kg/m²
  • Power Conditions: Capacity >22kVA, 3-phase 5-wire, Voltage 220/380V, Frequency 50Hz (Live wire: Yellow/Green/Red, Neutral wire: Blue, Ground wire: Yellow-green)
HWF80-04N Series Precision Atmosphere-Controlled Vacuum Muffle Furnace with 400°C Max Temperature 15kW Heating Power and ±1°C Accuracy 1 HWF80-04N Series Precision Atmosphere-Controlled Vacuum Muffle Furnace with 400°C Max Temperature 15kW Heating Power and ±1°C Accuracy 2 HWF80-04N Series Precision Atmosphere-Controlled Vacuum Muffle Furnace with 400°C Max Temperature 15kW Heating Power and ±1°C Accuracy 3